Application: sludge / self priming

Sludge liquor must be self primed from an underground tank. The sludge level in the tank is deter-mined ultrasonically. A PLC controls with a VFD the speed related capacity of the BÖRGER Rotary Lobe Pump.

technical specifications:
Pump FL 1036
Q 80-180 m3/h 352-792 USGPM
P max. 5 bar max. 72.5 psi
n max. 350 RPM .
P 4.5 KW 10 HP
DS content app. 0.5-1% .

BÖRGER GmbH • Benningsweg 24 • D-46325 Borken-Weseke • GERMANY
Tel.: +49 (0) 28 62 / 91 03 - 20 • Telefax: + 49 (0) 28 62 / 91 03 - 46